Flow Rate
– A read-only field showing the current flow rate registered by LCR.iQ during a
delivery.
Pulser Reversals
– A read-only field that accounts for any quadrature pulser faults registered
by the LCR.iQ during a delivery.
Calibration #
– A read-only counter that increments one number each time the LCR.iQ enters
the calibration mode. This field is for metrological and troubleshooting use only.
Last Calibration Date
– A read-only field displaying the last date and time the LCR.iQ entered
into the calibration mode.
Calibration Event #
– A read-only counter that increments one number each time the LCR.iQ
enters the calibration mode and a calibration change is made. This field only increments one
time per entry into calibration even if multiple changes are made. This field is for metrological
and troubleshooting use only.
Configuration Event #
– A read-only counter that increments one number each time (a) the
LCR.iQ enters the calibration mode and (b) a configuration field changes. This field only
increments one time per entry into calibration even if multiple changes are made. This field is
for metrological and troubleshooting use only.
Diagnostics Screen 2/6
Register State
– provides a real time view of the current status of the key LCR.iQ state fields.
This is useful to see if a parameter is active (Yellow), not active (White) or in an error state
(Red).