LCR.iQ - Setup and Operations Manual
78
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
·
Forward
Count
Only
- A registered pulse signal, in the forward direction only, will directly
affect the accumulative totalizer readings. It will also display the volume on the idle
delivery screen.
·
Ignore
- Any pulse signal that is detected when a delivery is not active will be ignored by
the LCR.iQ.
·
Reverse Count Only
- A registered pulse signal, in the reverse direction only, will directly
affect the accumulative totalizer readings. It will also display the volume on the idle
delivery screen.
Decimal Digits
– A list box field that sets the decimal place for the displayed volume and also
the shift and accumulative totalizers.
Options:
·
Tenths
- Sets the decimal place to the tenth unit position (xxxxx.x)
·
Whole
- Sets the decimal place to the whole units position (xxxxxx)
·
Hundredths
- Sets the decimal place to the hundredths position (xxxx.xx)
Temperature
– This is numeric-only text field displays the current temperature sensed by the
LCR.iQ temperature probe when installed. Use this field to set a temperature offset field, if the
value is within the allowed range of the temperature offset field below. If no probe is installed,
this value will read
--.-
.
Temperature Offset
– A numeric-only text field for specifying an offset to the value of the
current temperature reading. A value of +/- .54 degrees F or +/- .3 degrees C is allowed by
Weights and Measures. When an offset is entered and within the acceptable range, the
current temperature will automatically be adjusted by the amount of this value.
(Floating
point from -.30 to +.30°C or -.54 to +54°F)