LCR.iQ - Setup and Operations Manual
13
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
·
Current: 3 mA maximum sink current
·
Maximum Frequency: 10 kHz
OUTPUTS
The LCR.iQ is equipped with six digital outputs and four solenoid outputs. These outputs allow
the LCR.iQ to communicate with meter system accessories such as solenoid- controlled
valves, optical air and vapor eliminators, remote displays, printers, and third-party devices.
Digital Outputs 1, 2, 3, 4, 5, and 6
·
Open drain output, active low to ground, thermally protected
·
Voltage: 5 to 28 VDC
·
Current: 500 mA maximum
Outputs for solenoids 1, 2, 3, and 4
·
Open drain output, active low to ground, thermally protected
·
Voltage: 12 VDC nominal
·
Current: 1 A maximum
·
Voltage: 24 VDC nominal
·
Current: 0.5 A maximum
Pulse Output
·
Voltage peak to peak – 5 to 28 V
·
Frequency maximum – 7500 Hz
Scale Pulse Output
·
Current sinking capability: 150 mA