LCR.iQ - Setup and Operations Manual
79
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
Meter (2/3)
Valve Logic Type
– A list box field that is used to select the logic to be used when connecting
a solenoid valve to the LCR.iQ.
Options:
·
Two-Stage Preset Valve
- This logic is to be used with standard 2 stage preset valves.
With this logic, only S1 will open for full flow when a delivery starts. S2 will only open for
dwell (slow) flow. This logic is the same as current LCR registers.
·
Single/Dual Option Preset Valve
- This logic can be used when using single or dual
stage preset valves. With this logic both S1 and S2 will energize at the start of a delivery.
If an S1 close time is set, S1 will drop out when the S1 close is reached and S2 will
remain open until the final closure amount reached.