LCR.iQ - Setup and Operations Manual
7
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
OBSERVE NATIONAL & LOCAL CODES
Power, input, and output (I/O) wiring must be in accordance with the area
classification for which it is used (Class I, Div 2). For North America, installations
must be per the U. S. National Electrical Code, NFPA 70, or the Canadian
Electrical Code in order to maintain Class I, Division 2 ratings. This may require
using connections or other adaptations in accordance with the requirements of
the authority having jurisdiction.
Peripheral equipment must be suitable for the hazardous location where it is
installed. (L'équipement périphérique doit être adapté à la zone dangereux où il
est installé.)
WARNING: Explosion Hazard
When in hazardous locations, turn power OFF before replacing or wiring
modules. (Lorsque dans des endroits dangereux, coupler le courant avant de
remplacer ou de câbler des modules.)
DO NOT disconnect equipment unless power has been switched OFF or the area
is known to be Non-Hazardous. (NE PAS déconnecter l'équipement san coupler
l'alimentation ou sans s'assurer que la zone est non dangereuse.)
WARNING:
Use 3.5 in • lb (0.4 N • m) torque when tightening terminal block
screws.