LCR.iQ - Setup and Operations Manual
9
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
The Epson Printer Ground Wire Kit is included with each Epson printer cable kit shipment. For
existing installations and previously purchased registers / printers, both ground kits are
available from LC.
Grounding with a Meter Mount or Remote Mount
In a LCR.iQ installation where the register is mounted directly to the meter, the LCR.iQ
housing is grounded through the meter. If the register is not mounted on the meter, you must
ensure the LCR.iQ housing is grounded properly.
Alternate grounding methods for remote mounted registers
For installations where grounding the register housing through a mount is not possible, an
external grounding screw hole is available. This hole requires a #8-32 x 1/4” ground screw–
which is supplied with the register (the LC part number for the screw is 08254)–and also a 12
gauge or larger stranded wire connected to a known ground (less than 1 ohm).
Another option is to connect the ground screw 8-32 x 1/4” ground screw (inside the LCR.iQ
housing) to a 12 gauge or larger stranded wire connected to a known ground (less than 1
ohm).