April 17, 2000
Man ual Versio n 1.0
5.4
rotary transducer mounted on the slide system of the press. The units for the
position can be in inches or millimeters depending on the configuration. See
section 4.2.2 for details.
Fault
If the slide adjust system detects an error it will be reported on this line. A fault
occurs when a hardware or firmware problem is diagnosed by the system. See
section 6 for fault messages and their meanings.
Status
The current status of the slide adjust system. Status messages indicate what the
system is doing in the normal course of its operation. See section 6 for status
messages and their meanings.
Section 5.1.1 Slide On, Manual, and Off Settings
The Auto-Setup module allows three modes of operation to be chosen in the configuration menu for
each slide adjust system - “ON”, “MAN” (manual), or “OFF”. ON is the proper mode for the normal
intended use of the system.
The operator or setup person cannot change the mode in the operation screen but the setting is reported
at the top of the slide adjust box after the slide name (“Slide Adjust #1" or “Slide Adjust #2") for
convenience.
The mode setting affects the operation of the slide system in the following ways:
“ON”
Jobs that are recalled will automatically move the slide to the position stored in
the job subject to the conditions described in section 5.1.2. The “AUTO
ADJUST” softkey can be used to initiate automatic movement of the slide to the
currently programmed setpoint. The “JOG UP” and “JOG DN” softkeys can be
used to manually move the slide.
“MAN” (manual)
This mode can be chosen if there is some reason the employer does not want to
allow recall of previously stored job setups from memory. The slide position will
not automatically change when a job is recalled. The slide setpoint can still be
changed by manual entry of the desired setpoint and by pressing the “AUTO
ADJUST” softkey to initiate an auto adjust sequence. The “JOG UP” and “JOG
DN” softkeys can be used to manually move the slide.
“OFF”
The slide position will not automatically change when a job is recalled. No
automatic movement will occur even if the “AUTO ADJUST” softkey is pressed.
The “JOG UP” and “JOG DN” softkeys will still move the slide. This mode is
provided to allow temporary reversion to completely manual adjustment of shut
height by use of the “JOG UP” and “JOG DN” softkeys if the slide mounted
transducer fails.
Section 5.1.2 Automatic Slide Movement
Automatic movement of the slide can be initiated by either pressing the “AUTO ADJUST” softkey in
Содержание OmniLink 5000
Страница 5: ...April 17 2000 Manual Versio n 1 0 iv...
Страница 38: ...April 17 2000 Manual Versio n 1 0 4 14...
Страница 63: ...April 17 2000 Manual Versio n 1 0 B 2 Figure B 2 Typical Cushion Wiring Diagram...
Страница 64: ...April 17 2000 Manual Versio n 1 0 B 3 Figure B 3 Conceptual Dual Resolver Mounting...
Страница 65: ...April 17 2000 Manual Versio n 1 0 B 4 Figure B 4 Typical AMCI Dual Resolver Wiring Diagram...
Страница 66: ...April 17 2000 Manual Versio n 1 0 B 5 Figure B 5 Typical GEMCO Dual Resolver Wiring Diagram...
Страница 67: ...April 17 2000 Manual Versio n 1 0 B 6 Figure B 6 Conceptual Linear Transducer Mounting...
Страница 68: ...April 17 2000 Manual Versio n 1 0 B 7 Figure B 7 Typical GEMCO Linear Transducer Wiring...
Страница 69: ...April 17 2000 Manual Versio n 1 0 B 8 Figure B 8 Typical MTS Temposonics II Linear Transducer Wiring...
Страница 71: ...April 17 2000 Manual Versio n 1 0 B 10...
Страница 73: ...April 17 2000 Manual Versio n 1 0 C 2...