![Lightware MX-FR17 Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/lightware/mx-fr17/mx-fr17_user-manual_1915313044.webp)
4. Operation
MX-FR Series Modular Matrix Frames – User's Manual
44
Applied CPU2 firmware: v3.5.7b8 | LDC software: v2.5.17b2
4.4.6.
Switching Operations Flowchart
Take Mode
#takemode
Autotake Mode
source
button
pressed
destination
button
pressed
idle
TAKE
mode
viewing
source
connections
viewing
destination
connection
select or
deselect
destinations
connections
realized
previewing
connections
TAKE
button
pressed
same
button
pressed
all outputs
preselected
nothing pressed for 3 sec
nothing pressed for 3 sec
destination
button
pressed
idle
AUTOTAKE
mode
viewing last destination’s
connection
select or
deselect
destinations
connection
realized
4.4.7.
Preset Operations
DEFINITION:
A
preset
stores a configuration regarding all input connections and mute state for all
outputs.
#preset
INFO:
All Lightware matrix routers have 32 user programmable presets. All presets are stored in a non-
volatile memory; the router keeps presets even in the case of a power down. Memory numbers are
assigned to source buttons 1 to 32. If the frame has fewer buttons, the higher numbered presets are
accessible only through software control.
Saving a Preset in Take Mode
Step 1.
Create the desired connections that need to be saved.
Step 2.
Press and release the
Save preset
button.
Step 3.
Press and release a
source
button according to the desired memory address (source 1 to 32).
Step 4.
Press and release the
Take
button.
Now the current configuration is stored in the selected memory.
ATTENTION!
Preset save action always stores the current configuration for all outputs including mute
state, but ignores lock state.