Troubleshooting
Understanding the printer messages
Cartridge, imaging unit mismatch [41.xy]
1
Check if the toner cartridge and imaging unit are both
MICR
(Magnetic Imaging Content Recording) or non-MICR
supplies.
Note:
For a list of supported supplies, see the “Ordering supplies” section of the
User's Guide
or visit
www.lexmark.com
.
2
Change the toner cartridge or imaging unit so that both are MICR or non
‑
MICR supplies.
Notes:
•
Use MICR toner cartridge and imaging unit for printing checks and other similar documents.
•
Use non-MICR toner cartridge and imaging unit for regular print jobs.
Cartridge low [88.xy]
You may need to order a replacement toner cartridge. If necessary, touch
Continue
on the printer control panel to
clear the message and continue printing.
Cartridge nearly low [88.xy]
If necessary, touch
Continue
on the printer control panel to clear the message and continue printing.
Cartridge very low, [x] estimated pages remain [88.xy]
You may need to replace the toner cartridge very soon. For more information, see the “Replacing supplies” section of
the
User’s Guide
.
If necessary, touch
Continue
on the printer control panel to clear the message and continue printing.
Change [paper source] to [custom string] load [orientation]
Try one or more of the following:
•
Load the correct size and type of paper in the tray, then specify the paper size and type in the Paper menu on the
printer control panel, and then touch
Finished changing paper
.
•
Touch
Reset active bin
to reset the active tray for a linked set of trays.
•
Cancel the print job.