1
AC
2
DC
3
Error
On
On
Off
Normal operation
The server is
functioning
correctly.
Off
Off
Off
No power to the power
supply, a problem with the
input power source, or the
power supply has failed.
1. Check the input power to
the server (voltage and
frequency).
2. Make sure that the power
cord is connected to a
functioning and
supported power source.
3. Replace the power
supply.
Off
Off
On
No input power to the power
supply or the power supply
has detected an internal
problem.
1. Make sure that the power
cord is connected to a
functioning power
source.
2. Replace the power
supply.
This happens
only when a
second power
supply is
providing power
to the server
Off
On
Off
The power supply has failed.
Replace the power supply.
Off
On
On
The power supply has failed.
Replace the power supply.
On
Off
Off
The system is shut down
(server is connected to
power).
The system has overloaded
the power supply.
Remove options or add an
additional power supply.
If the system is
shut down, this
is a normal
condition.
The LED may go
off for less than
a minute then
back on during
an input power
cycle operation
initiated by the
Lenovo XClarity
Controller.
On
On
Off
The system is on (normal
operation)
The system is on (not
operating): power-supply
not fully seated, faulty
system board, or faulty
power-supply.
1. Reseat the power supply.
2. Replace the power-
supply.
3. Replace the system
board.
It usually
indicates the
power supply is
not fully seated.
On
Off
On
Faulty power supply.
Replace the power supply.
On
On
On
Faulty power supply.
Replace the power supply.
248
User Guide for ThinkAgile VX7820 Appliance, ThinkAgile VX 4-Socket 4U Certified Node
Содержание ThinkAgile VX 4-Socket 4U Certified Node
Страница 6: ...iv User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 10: ...viii User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 69: ...Chapter 2 Server components 59 ...
Страница 76: ...66 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 96: ...86 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 252: ...242 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 276: ...266 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 284: ...274 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 295: ......
Страница 296: ......