Setting
FlexLine, 45
ALL
Sets the trigger key with the same function as
ALL
.
DIST
Sets the trigger key with the same function as
DIST
.
USER Key 1 /
Key 2
Configures
or
with a function from the FNC menu. Refer to "6
Functions".
Tilt Corr.
Off
Tilting compensation deactivated.
1-axis
Vertical angles refer to the plummet line.
2-axis
Vertical angles refer to the plummet line and the
horizontal directions are corrected by the standing
axis tilt.
For corrections depending on the
Hz Corr:
setting,
refer to the table "Tilt and horizontal corrections".
If the instrument is used on an unstable base, for example a shaking
platform or ship, the compensator should be deactivated. This
avoids the compensator drifting out of it's measuring range and
interrupting the measuring process by indicating an error.
Field