FlexLine, 284
Technical Data
14.6
General Technical Data of the Instrument
Telescope
Compensation
Quadruple axis compensation (2-axis compensator with Hz-collimation and V-Index).
Level
Magnification:
30 x
Free Objective aperture:
40 mm
Focusing:
1.7 m/5.6 ft to infinity
Field of view:
1°30’/1.66 gon.
2.7 m at 100 m
Angular accuracy Setting accuracy
Setting range
["]
["]
[mgon]
[’]
[gon]
1
0.5
0.2
±4
0.07
2
0.5
0.2
±4
0.07
3
1
0.3
±4
0.07
5
1.5
0.5
±4
0.07
7
2
0.7
±4
0.07
Circular level sensitivity:
6’/2 mm
Electronic level resolution:
2"