Tools
FlexLine, 67
5.2
Start Up Sequence
Description
Through the Startup tool, it is possible to record a user defined sequence of key
presses so that, after switching on the instrument, a particular screen can be
displayed after the Level/Plummet screen instead of the
MAIN MENU
. For example,
the general
SETTINGS
screen for configuring the instrument settings.
Access
1. Select
TOOLS
from the
MAIN MENU
.
2. Select
Startup
from the
TOOLS MENU
.
Auto start
step-by-step
1. Press
RECORD
in the
AUTO START
screen.
2. Press
OK
to confirm the information message and begin the recording process.
3. The next key presses are stored, up to a maximum of 16. To end the recording
press
ESC
.
4. If the auto start
Status
: is set to
Active
, the stored key presses will be executed
automatically after switching on the instrument.
Adjust
Reminder
Defines the time period from the last adjustment to when a
reminder message should display to do another adjustment.
Options are:
Never
,
2 weeks
,
1 month
,
3 months
,
6 months
,
12 months
.
The message will display the next time the instrument is switched
on after the time period has been reached.
Menu selection Description