Technical Data
FlexLine, 281
14.4
Distance Measurement Reflector (>3.5 km)
Range
Atmospheric
conditions
Accuracy
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
Ultra&Power (with
reflector)
Range A
Range B
Range C
[m]
[ft]
[m]
[ft]
[m]
[ft]
Standard prism (GPR1)
2200
7300
7500
24600
>10000
>33000
Reflector tape
60 mm x 60 mm
600
2000
1000
3300
1300
4200
Range of measurement:
From 1000 m up to 12000 m
Display unambiguous:
Up to 12 km
Range A:
Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer
Range B:
Light haze, visibility about 20 km; or moderate sunlight, slight heat
shimmer
Range C:
Overcast, no haze, visibility about 40 km; no heat shimmer
Standard
measuring
Standard deviation
ISO 17123-4
Measure time,
typical [s]
Measure time,
maximum [s]
Long range
5 mm + 2 ppm
2.5
12