Setting
FlexLine, 53
Mask3
StationID, E, N, H, hi (Station).
StationID, Ori, E, N, H, hi (Station Result).
PtID, E, N, H (Control).
PtID, Hz, V (Set Azimuth).
PtID, Hz, V, SD, ppm+mm, hr, E, N, H
(Measurement).
Code record
Sets if the codeblock is saved before or after the measurement.
Refer to "7 Coding".
Code
Sets if the code will be used for one, or many, measurements.
Reset after
REC
The set code is cleared from the measurement
screen after
ALL
or
REC
is selected.
Permanent
The set code remains in the measurement screen
until manually deleted.
Display ill.
Off
to
100%
Sets the display illumination in 20% steps.
Reticle ill.
Off
to
100%
Sets the reticle illumination in 20% steps.
Displ.Heater
On
The display heater is activated.
Off
The display heater is deactivated.
The display heater is automatically activated when the display
illumination is on and the instrument temperature is
5°C.
Pre-/Suffix
Only used for the Stakeout application.
Field
Description