Applications
FlexLine, 207
Repetitive loop for
the number of sets
Alternating between screens for the backsight and foresight measurements
continues according to the configured number of sets.
The number of sets and the face are indicated in the top right corner of the screen.
For example 1/I means set 1 in face I.
9.14.4
Moving ahead
Number of defined
sets is achieved
When the number of defined sets is achieved, the
TRAVERSE MAIN
screen is
displayed automatically.The accuracy of the set measurements is checked. The set
can be accepted or redone.
Redo whole
station
Returns to first sight point screen. The data from the last station
is not stored.
Exit traverse
Returns to the
PROGRAMS
menu. The traverse stays active and
can be continued later. The data from the last station is lost.
PREV
Returns to the previous screen where
ESC
was pressed.
Field
Description