FlexLine, 218
Applications
The perpendicular distance to the plane can be positive or negative.
Access
1. Select
Prog
from the
MAIN MENU
.
2. Select
Ref Plane
from the
PROGRAMS
menu.
3. Complete application pre-settings. Refer to "8 Applications - Getting Started".
Measure plane and
target points
1. Once the plane has been defined by three points, the
Measure Target point
screen appears.
2. Measure and record the target point. The results are displayed in the
REFERENCE
PLANE RESULT
screen.
P1
Origin of plane
X
X-axis of plane
Y
Y-axis of plane
Z
Z-axis of plane
d1
Positive offset
d2
Negative offset
TSOX_121
Z
Y
X
P1
d1
d2