FlexLine, 276
Technical Data
14
Technical Data
14.1
Angle Measurement
Accuracy
Characteristics
Absolute, continuous, diametric. Updates each 0.1 to 0.3 s.
Available
angular
accuracies
Standard deviation
Hz, V, ISO 17123-3
Display resolution
["]
[mgon]
["]
[°]
[mgon]
[mil]
1
0.3
0.1
0.0001
0.1
0.01
2
0.6
1
0.0001
0.1
0.01
3
1.0
1
0.0001
0.1
0.01
5
1.5
1
0.0001
0.1
0.01
7
2
1
0.0001
0.1
0.01