FlexLine, 62
Setting
The refraction correction is taken into account in the calculation of the height
differences and the horizontal distance. Refer to "14.7 Scale Correction" for the
application of the values entered in this screen.
PROJECTION SCALE
This screen enables entry of the scale of projection. Coordinates are corrected with
the PPM parameter. Refer to "14.7 Scale Correction" for the application of the values
entered in this screen.
Enter individual
PPM
This screen enables the entry of individual scaling factors. Coordinates and distance
measurements are corrected with the PPM parameter. Refer to "14.7 Scale
Correction" for the application of the values entered in this screen.
EDM SIGNAL
REFLECTION
This screen tests the EDM signal strength (reflection strength) in steps of 1%. Enables
optimal aiming at distant, barely visible, targets. A percentage bar and a beeping
sound, indicate the reflection strength. The faster the beep the stronger the reflection.
4.3
Communication Parameters
Description
For data transfer the communication parameters of the instrument must be set.
Access
1. Select
Settings
from the
MAIN MENU
.
2. Select
Comm
from the
SETTINGS MENU
.
When PPM=0 is selected, the Leica standard atmosphere of 1013.25 mbar,
12°C, and 60% relative humidity will be applied.