Applications
FlexLine, 205
With known
backsight
Start a traverse with a known backsight
• Start on a known point with an intial measurement to a known backsight.
• Stop on a known point and optionally measure to a known closing point.
With known
azimuth
Start a traverse with a known azimuth
• Start on a known point, aim to any direction (e.g. a tower) and define this
direction as the reference. This method is often used to define a 0-direction.
• Stop/end the traverse either on a known point or a traverse point and then
measure to a known closing point, or leave the traverse open. Refer to "9.14.5
Closing a Traverse".
If using the current system azimuth, for example from the Station Setup application,
then simply confirm the suggested Hz-value in the
Set Horizontal Angle
screen.
Measure traverse -
Sight backsight
C1, C2
Control points
C4, C5
Control points
C3
Check point
P1...P3
Traverse points
TP1...TP3
Topographic points
N
North direction
C1
C2
P1
P2
P3
C4
C5
TP3
TP2
TP1
C3
N
N
TSOX_059
Field
Description
BS ID
Point ID of the backsight point.