edge - User Manual
Version: 1.0.13/1
Exported on: 22 February, 2024
80
/
154
To identify a processing blade, either press and hold
Call Home
(on the unit) for at least 2 seconds or
select
Identify
Hardware
(in HOME's General
tab).
When
Call Home
or
Identify Hardware
is active, a
“Says Hi”
message appears in the HOME Web UI (as shown here).
To cancel the "Identify Hardware" mode, either deselect
Identify Hardware
(on the GUI) or press and hold the
Call
Home
button again (on the unit).
button can also be used to reset the network settings for the MGMT ports. This is described later
5. Reset
The
Reset
button can be used to reset the power of the processing blade. The button is recessed to prevent accidental
operation. After the reboot, the blade loads the latest configuration.
You can also reboot a processing blade remotely using the
Reboot
option (from HOME's "Devices" list).
6. USB-C
The
USB-C
(port) is provided for diagnostics. In the event of a problem, you may be asked to connect this port to a service
computer by a Lawo support engineer. The connection should be made using a standard USB Type-C cable.
7. Card Status
The
Card Status
LED shows the health of the processing blade (and chassis*). The LED has three possible states: green,
amber or red.
Card Status LED
Meanin
g
Recommended Actions
Green,
intermittent
Ok
No action required.
Amber,
intermittent
Warning
Check the
Card Warning(s)
on the System controls
parameters).
Red, blinking
Fault
Check the
Card Fault(s)
page (in HOME's Advanced parameters).
*On the master processing blade (fitted to the highest physical slot), the
Card Status
LED shows
the health of both the
card (blade) and chassis (frame). Typically, the chassis faults are either power or fan-related. e.g. If there is a power fault in
the frame, then the top
Card Status
LED lights in red while all other
Card Status
LEDs are green.
8. SDI Interfaces
Each rear I/O plate is equipped with 48 x HD-BNC for SDI
interfacing.
The number of available SDIs is determined by the number of ".edge_sdi" licenses on the processing
blade. In
addition, the
number of SDI inputs versus outputs can be changed using
Device Options (in HOME's General tab).
A processing blade can be reset to its factory default settings using the
in HOME's
Advanced
parameters).
Содержание edge
Страница 43: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 43 154...
Страница 58: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 58 154...
Страница 87: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 87 154 IP Senders audio sender properties...
Страница 90: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 90 154 IP Receivers audio receiver properties...
Страница 98: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 98 154...
Страница 103: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 103 154...
Страница 113: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 113 154...
Страница 126: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 126 154...
Страница 130: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 130 154...