Lantronix
ION x6010 User Guide
33493 Rev. F
Page 111 of 261
Command
:
Go to another location
Syntax
:
go
<location string>
Description
: Set the location to device/port of the SIC to be operated.
Usage
:
go
[c=<0-16>] [s=<0-32>] [l1ap=<1-15>] [l2ap=<1-15>] (l1p=<1-5>|l2p=<1-15>|l3p=<115>|l1d|l2d|l3d)
Example
:
C1|S1|L1D>
go c=1 s=4 l1d
C1|S4|L1D>
go c=1 s=6 l1d
Invalid location parameters, cannot find the physical entity!
C1|S4|L1D>
go c=1 s=8 l1d
C1|S8|L1D>
go c=1 s=8 l1p=1
C1|S8|L1P1>
Command
:
Show TDM Configuration
Syntax
:
show tdm config
<cr>
Description
:
A system-level command that displays the x6010 TDM type (the current x6010 device’s
operating mode, either
T1
or
E1
).
Note
: at the port level, use the
show tdm port conf
ig
command.
Example
:
Agent III C1|S2|L1D>
show tdm ?
config
inband
loopback
peer
port
Agent III C1|S2|L1D>
show tdm config
tdm type: t1
Agent III C1|S2|L1D>
Command
:
Show
TDM Loopback Capability
Syntax
:
show tdm loopback capability
<cr>
Description
:
A port-level command that displays the port’s TDM loopback setting (either
noLoopback or phyLayer).
Example
:
Agent III C1|S2|L1D>
show tdm loopback capability
Error: this command should be executed on a port!
Agent III C1|S2|L1D>
go l1p=1
Agent III C1|S2|L1P1>
show tdm loopback capability
Loopback capability: phyLayer
Agent III C1|S2|L1P1>
go l1p=2
Agent III C1|S2|L1P2>
show tdm loopback capability
Loopback capability: phyLayer
Agent III C1|S2|L1P2>