Lantronix
ION x6010 User Guide
33493 Rev. F
Page 252 of 261
Appendix E Local Management of Cards in a Remote Un-
managed Chassis
This appendix discusses managing the link between an ION Managed Chassis (MC) and an Un-managed
Chassis (UC), and performing remote firmware upgrades.
ION x6210 FW v1.2.6 adds support for management of a C6210 when installed in an unmanaged ION
chassis. Management is supported by another C6210 installed in a managed chassis when the two are
linked together via a fiber cable. FW v1.2.6 also adds support for remote firmware upgrades of a C6210
in an unmanaged chassis.
Previous Status
In previous firmware versions (e.g., x6010 / x6020 before v 1.2.6):
•
All cards in an ION chassis can be managed via the IONMM.
•
Some cards support remote management of a linked stand-alone, in-band, over the fiber, by the
card in a local Managed Chassis (MC):
o
Ethernet: x2220, x3220, x3230, x4120
o
TDM:
x6010, x6110, x6120, x6210
•
Some cards do not support remote management of a linked stand-alone:
o
x2110, x2210, x3100, x3110, x3210, x4110
Local Management of a Remote Unit
:
Focal Point
ION System
In firmware versions before v 1.2.6, support includes:
A local Managed Chassis with an IONMM can manage a remotely managed standalone
A local Managed Chassis with an IONMM can manage a remotely managed card in a 1- or 2-Slot ION
Chassis
Not supported in firmware versions before v 1.2.6:
□
Remote 19-slot Managed Chassis cannot manage a remote Un-managed Chassis that has no
IONMM
In x6010 / x6020 firmware versions v 1.2.6 and after, Managed Chassis (MC) to Un-managed Chassis
(UC) is supported with a firmware upgrade to the slide-in-card (S6010/S6020 v 1.2.6).
Note
that no firmware upgrade to the IONMM is required.