Lantronix
ION x6010 User Guide
33493 Rev. F
Page 76 of 261
Backing Up Standalone Modules
The following procedure describes how to back up the configuration of a standalone module.
IMPORTANT
Doing a reboot, restart, an upgrade or a reset to factory settings may cause some configuration
backup files, HTTPS certification file, and Syslog file to be lost. Doing a reboot, restart or upgrade of the
IONMM, a power restart of the chassis, or a reset to factory removes temporary files (e.g. configuration
backup files, Syslog file). A Factory Reset also removes the permanent settings (e.g. configuration files,
HTTPS certification file, SSH key).
1.
Access the IONMM module through the Web interface (see
“Starting the Web Interface”
).
2.
Select the
BACKUP-RESTORE
tab.
3.
In the
Select
column, check the checkbox of the module to be backed up (C6010-3040 in slot 05 –
Index #4 in the screen above). The attached standalone is REM S6010-1040 in slot 05 – Index #5