Temperature
Alarm
Normal -1,
Not Supported – 2,
Low Warn – 3,
High Warn – 4,
Low Alarm – 6
High Alarm – 7
Alarm status for temperature of fiber transceiver.
An
ionDMITemperatureEvt
event is sent when there is a warn-
ing or alarm on DMI temperature
Transmit Bias
Current (uA)
(measured current)
Transmit bias current on local fiber interface, in uA (microam-
peres). The sample screen above shows 15440 uA (micro-
amps).
Transmit Bias
Alarm
Normal -1,
Not Supported – 2,
Low Warn – 3,
High Warn – 4,
Low Alarm – 6
High Alarm – 7
Alarm status for transmit bias current on local fiber interface.
Transmit
Power (uW)
(measured power) Transmit power on local fiber measured in microwatts.
The sample screen above shows
244
uW (microwatts).
Transmit
Power (dBM) (measured power)
Transmit power on local fiber measured in dBM (decibels rela-
tive to one milliwatt) which defines signal strength.
The sample screen above shows -6.126 dBM.
Transmit
Power Alarm
Normal -1,
Not Supported – 2,
Low Warn – 3,
High Warn – 4,
Low Alarm – 6
High Alarm – 7
Alarm status for transmit power on local fiber.