Incomplete location command!
Incomplete location parameters, lack of level1 attachment port!
This message indicates that one or more parameters for the
go
command are missing. The
go
command
was entered to set location parameters, but the module, slot and/or port value(s) were not included in
the command string.
The
go
command can operate on a local or remote card/port, and you must give the last parameter to
specify the target is a port or device. For example, the input go c=1 s=14 does not include the port
parameter, so the CLI module displays “Incomplete location parameters”.
1.
Verify the command syntax.
2.
Re-enter the
go
command and be sure to include all of the location parameters:
go [c=CHASSIS] [s=SLOT] [l1ap=L0APORT] [l2ap=L1APORT] (l1p=PORT|l2p=PORT|l3p=PORT|l1d|l2d|l3d)
3.
If the problem persists, contact Technical Support.
Invalid condition value: xxxx
This message indicates that the input for the value= parameter on the command in not valid.
1.
Verify the value being input; it must match with the value input for
type
=.
2.
Retry the operation.
3.
If the problem persists, contact Technical Support.
Invalid location parameters, cannot find the physical entity!
This message indicates that the system cannot detect the presence of the device or port specified in the
go
command.
1.
Verify that the correct hierarchy has been specified in the command (see
“Managing Slide-In and
Remote Modules Using CLI Commands”
).
2.
For all modules (slide-in and remote) check the following:
•
module is properly seated/connected
•
module is powered up
3.
Wait 60 seconds then retry the operation.
4.
Cycle power for the module in question.
Note:
for slide-in modules pull the module out so it is no
longer connected to the backplane, then slide the module back in, ensuring that it is firmly seated.
5.
Retry the operation.
6.
If the problem persists, contact Technical Support.