Lantronix
ION x6010 User Guide
33493 Rev. F
Page 90 of 261
Reboot
At times you may have to reboot (restart) the ION system. This operation can be accomplished by either
the CLI or Web method.
Note
: this operation can take several minutes. The amount of time for the reboot to complete depends
on the ION system configuration. When the reboot is finished, some devices (usually remote devices)
will show the error condition of a “red box” around items like IP address, Trap Manager IP addresses,
and/or DNS Entries. The ‘red box’ condition occurs while the devices are resetting; this condition can
continue several minutes after the reboot.
See Table 19 in this section for file content and location after a System Reboot.
IMPORTANT
Doing a system reboot, restart, upgrade, or a reset to factory settings may cause some
configuration backup files, HTTPS certification file, and Syslog file to be deleted.
Rebooting – CLI Method
1.
Access the NID through either a USB connection (see
“Starting a USB Session”
) or a Telnet session
(see
“Starting a Telnet Session”
).
2.
At the command prompt type:
reboot
and press
Enter
. A warning displays:
this command will restart
system, connection will be lost and please login again!
The ION system device reboots. If this
operation is performed on a standalone module, the connection / session is terminated.
3.
To reestablish the connection / session, wait about one minute, and then:
•
For a USB connection
a)
Select
Call > Disconnect
.
b)
Select
File > Exit
.
c)
Disconnect then reconnect one end of the USB cable.
d)
Start a USB session (see
“Starting a USB Session”
).
•
For a Telnet session
a)
Press
Enter
.
b)
Start a Telnet session (see
“Starting a Telnet Session”
).