57
To drain
- Unscrew the fill plug (A).
- Place a container under the drain hole and unscrew the drain
plug (B).
To fill
- Replace the seal if necessary and refit the drain plug.
- Unscrew the level gauge plug (C) and fill the gearbox using a
funnel.
- Stop filling as soon as oil seeps through the level gauge hole.
- Refit the level gauge and fill plugs.
5.7.2
Conveyor Reduction Gear Unit
5.7.1
Gearbox
The gearbox must always have sufficient oil. Its capacity is 5 litres.
To drain
- Unscrew the fill plug (A).
- Place a container under the reduction gear
unit and unscrew the drain plug (B).
To fill
- Refit the drain plug.
- Unscrew the level gauge plug (C) and fill
the gear unit with ISO CKC 150 type oil, such
as SHELL OMALA 150.
- Stop filling as soon as oil seeps through the
level gauge hole.
- Refit the plugs (A) and (C).