61
Should the turbine become jammed, a special hook must be used to
unblock it (see page 44). In view of the high inertia of this system, forcing
the turbine disc to move manually can lead to serious risks of having a
finger severed by a blade.
l
The conveyor stops rotating in
the course of work
- Check the hydraulic connections for leaks.
- Check that the feed rotor is engaged and the indicator is lit
(see section 1.6 Description of the Controls).
l
The feed rotor and the conveyor
stop rotating in the course of
distribution
- Check the hydraulic connections for leaks.
- Check that the indicator is lit (see section 1.6 Description of
the Controls).
- Check that the clutch is fully engaged (ram rod fully retracted,
see photo above). If not, make sure that the clutch ram does
not have an internal leak.
l
Turbine fails to rotate and
- Check that there is no product build-up in the turbine.
overload clutch slipping
If this is the case, use the hook mounted on the left-hand side
of the machine to pull out the jammed product at the delivery
chute or feed rotor, then use a lever to ensure that the turbine
can rotate freely. Once released, run the turbine empty for a
few seconds until it reaches its normal working speed.
You can also gain access to the turbine interior via the
flap (A) on the front of the machine.
A