48
- With the aid of the speed control lever, the unit may be used in three ways:
- at neutral, therefore without running the turbine, for all loading operations
- with a turbine speed of 270 min
-1
for distribution
- with a turbine speed of 540 min
-1
.
Maintenance:
- Comply with the safety instructions relating to machine maintenance.
- Periodically check the oil level in the tank. The oil level should not be below the top 1/3 of the gauge.
- Change the hydraulic oil after the first 500 hours of work. We recommend an ISO VG 46 (HV) type
hydraulic oil. For example: SHELL HYDRAU PW.
- Thereafter, refer to the maintenance chart for the frequency of oil changes.
- To change the filter element, unscrew the plug. Take hold of the filter handle and extract the
bowl assembly. To remove the filter, turn 90° anticlockwise and extract it from its cartridge. Clean the
bowl.
- Insert a new filter and lock into position by turning it 90° clockwise.
- Screw in the plug and make sure that the seal is correctly repositioned to prevent leaks.
4.2 FREE-WHEEL HOMOKINETIC TRANSMISSION
Transmission assembly providing a greater angle of deflection and free rotation of the turbine.
Before using this equipment, please consult the manual delivered with the transmission.
4.3 WEIGHING SYSTEM
Device used to determine the weight of the ration to be fed to the livestock.
Please read the instructions provided with the weighing system
carefully.