KFU-
tronic
41
1.150
Rotational direction
Unit: integer
min: 0
max.: 7
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (to
be entered!)
Relationship to
parameter:
1,131
Selecting the rotational direction specification
0 = dependent on target value (depending on the plus or minus sign of the
target value: positive: forward; negative: backwards)
1 = forwards only (rotational direction cannot be changed)
2 = backwards only (rotational direction cannot be changed)
3 = digital input 1 (0 V = forwards, 24 V = backwards)
4 = digital input 2 (0 V = forwards, 24 V = backwards)
5 = digital input 3 (0 V = forwards, 24 V = backwards)
6 = digital input 4 (0 V = forwards, 24 V = backwards)
7 = reference from KFU-tronic Soft-PLC
1.180
Reset Unit:
integer
min: 0
max.: 4
Parameter manual:
p. xy
Transfer status:
2
def.: 4
own value (to
be entered!)
Relationship to
parameter:
1,181
1,182
Selection of the source for error confirmation.
Errors can only be confirmed once the error has been removed.
Some errors can only be confirmed by switching the control off and then
on again,
see list of errors.
Auto-confirmation via parameter 1,181.
0 = no manual confirmation possible
1 = rising shoulder at digital input 1
2 = rising shoulder at digital input 2
3 = rising shoulder at digital input 3
1.181
Automatic reset
Unit: s
min: 0
max.:1,000,000
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (to
be entered!)
Relationship to
parameter:
1,180
1,182
Next to the reset function (1,180), an automatic reset can be selected.
0
= no automatic confirmation
Содержание KFUtronic Series