KFU-
tronic
50
6.3.8
Digital outputs
For digital outputs 1 and 2 (DOx display DO1/DO2)
4.150/4.170
DOx function
Unit: integer
min: 0
max.: 50
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (to
be entered!)
Relationship to
parameter:
4,151/4,171
4,152/4,172
Selection of the process value to which the output should switch.
0 = not allocated / KFU-TRONIC Soft-PLC
1= intermediate circuit voltage
2= supply voltage
3= motor voltage
4= motor current
5= actual frequency
6= –
7= –
8= IGBT temperature
9= interior temperature
10= error (NO)
11= inverted error (NC)
12= final release levels
13= digital input1
14= digital input 2
15= digital input 3
16= digital input 4
17= ready for operation
18= ready
19= operation
20= ready for ope ready
21= ready for ope ready + operation
22= ready + operation
23 = motor power
24 = torque
25 = field bus
4.151/4.171
DOx on
Unit:
min: 0
max.:1,000,000
Relationship to
parameter:
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (to
be entered!)
Содержание KFUtronic Series
Страница 5: ...KFU tronic 4 ...
Страница 31: ...KFU tronic 30 5 3 Block diagram General structure of target value generation ...