6.4
Performance parameters
6.4.1
Motor data
33.001
Type of motor
Unit: Integer
min: 1
max.: 2
Parameter manual:
S. xy
Transfer status:
1
def.: 1
own value (to
be entered!)
Relationship to
parameter:
34,010
Selecting the type of motor
1 = asynchronous motor
2 = synchronous motor
The parameters are shown depending on the type of motor selected.
33.015
R optimisation
Unit: %
min: 0
max.: 200
Relationship to
parameter:
Parameter manual:
p. xy
Transfer status:
1
def.: 100
own value (to
be entered!)
33.031
Motor current
Unit: A
min: 0
max.: 150
Parameter manual:
p. xy
Transfer status:
1
def.: 0
own value (to
be entered!)
Relationship to
parameter:
5,070
This is used to set the nominal motor current I
M,N
for either the star or tri-
33.032
Motor power
Unit: W
min: 0
max.: 680
Parameter manual:
p. xy
Transfer status:
1
def.: 0
own value (to
be entered!)
Relationship to
parameter:
A performance value [kW] P
M,N
has to be set here that corresponds to the
33.034
Motor speed
Unit: rpm
min: 0
max.:10,000
Parameter manual:
p. xy
Transfer status:
1
def.: 0
own value (to
be entered!)
Relationship to
parameter:
34,120
The value from the motor's type plate data has to be entered here for the