![Küenle KFUtronic Series Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/kuenle/kfutronic-series/kfutronic-series_instruction-manual_2009352062.webp)
KFU-
tronic
61
34.110
Slip trimmer
Unit:
min: 0
max.: 1.3
Parameter manual:
p. xy
Transfer status:
2
def.: 1
own value (to
be entered!)
Relationship to
parameter:
33,034
Only for asynchronous motors.
This parameter can be used to optimise or deactivate slippage compensa-
tion.
0 = deactivated (performance as on the grid)
34.130
Voltage control reserve
Unit:
min: 0
max.: 2
Parameter manual:
p. xy
Transfer status:
2
def.: 0,95
own value (to
be entered!)
Relationship to
parameter:
Only for asynchronous motors.
6.4.5
Squared characteristic
34.120
Squared characteristic
Unit: integer
min: 0
max.: 1
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (to
be entered!)
Relationship to
parameter:
34,121
Only for asynchronous motors.
The quadratic characteristic curve function can be activated here.
0 = disable
34.121
Flux compensation
Unit: %
min: 0
max.: 100
Parameter manual:
p. xy
Transfer status:
2
def.: 50
own value (to
be entered!)
Relationship to
parameter:
34,120
Only for asynchronous motors.
The percentage by which the flux is to be reduced can be set here.
An overvoltage shutdown can occur if there are any major changes in op-
Содержание KFUtronic Series
Страница 5: ...KFU tronic 4 ...
Страница 31: ...KFU tronic 30 5 3 Block diagram General structure of target value generation ...