6.4.3
Switching frequency
The internal switching frequency (clocking frequency) can be changed in order to control the
power element. A high setting reduces noise in the motor but increases EMV emission and
losses in the drive control.
34.030
Switching frequency
Unit: Hz
min: 1
max.: 4
Parameter manual:
p. xy
Transfer status:
2
def.: 2
own value (to
be entered!)
Relationship to
parameter:
Selection of the switching frequency for the converter
1 = 16 kHz
2 = 8 kHz
6.4.4
Controller data
34.010
Type of control
Unit: integer
min: 100
max.: 200
Parameter manual:
p. xy
Transfer status:
2
def.: 100
Own value (to
be entered!)
Relationship to
parameter:
33,001
34,011
Selection of the type of control.
100 = open-loop asynchronous motor
101 = close-loop asynchronous motor
200 = open-loop synchronous motor
34.011
Type of encoder
Unit: integer
min: 0
max.: 2
Parameter manual:
p. xy
Transfer status:
2
def.: 0
Own value (to
be entered!)
Relationship to
parameter:
34,010
34,012
34,013
Selection of the type of sensor
0 = inactive
1 = TTL sensor
2 = HTL sensor
WARNING
When selecting the HTL sensor, 24V is transmitted via the interface.