KFU-
tronic
35
Preset speed:
In this operating mode, preset speed references are transferred to the motor control. There are 7
preset speeds (2,051 to 2,057) that are BCD coded and attached fixedly to digital inputs 1 to 3.
These seven preset speeds can be released in three groups via the “preset speed mode” (2,050)
parameter:
0 = preset speed 1, 1 = preset speed 1 to 3, 2 = preset speed 1 to 7.
Logic table of fixed frequencies
DI 3
DI 2
DI 1
Selection
Parameters Presetting
0 0 0 Min.
frequency
1.020 0
Hz
0
0
1
preset speed 1
2.051
10 Hz
0
1
0
preset speed 2
2.052
20 Hz
0
1
1
preset speed 3
2.053
30 Hz
1
0
0
preset speed 4
2.054
35 Hz
1
0
1
preset speed 5
2.055
40 Hz
1
1
0
preset speed 6
2.056
45 Hz
1
1
1
preset speed 7
2.057
50 Hz