KFU-
tronic
66
No.
Error name
Description of fault
Possible cause/remedy
43 Ground
leak
Ground leak during a motor
phase
Insulation error
45
Motor connection dis-
rupted
No motor current in spite of con-
trol through frequency converter
No motor connected
46
Motor parameters
Plausibility check for motor pa-
rameters failed
Parameter set not OK
47
Drive control parameters Plausibility check for drive con-
trol parameters failed
Parameter set not OK
Please check the parame-
ters 33.001 and 34.010
48
Type plate data
No motor data were entered.
Please enter the motor
data according to the rat-
ing plate
49 Power-class
restriction Max overload of the drive con-
trol exceeded for more than 60
sec.
Check application / reduce
load / dimension larger
drive control