KFU-
tronic
58
33.201
Nominal flow
Unit: mVs
min: 0
max.: 5000
Parameter manual:
p. xy
Transfer status:
1
def.: 0
Own value (to
be entered!)
Relationship to
parameter:
For synchronous motors only.
The nominal flow can be optimised here if the automatically determined
6.4.2
I²T
33.010
I
2
T fact. motor
Unit: %
min: 0
max.: 150
Parameter manual:
p. xy
Transfer status:
2
def.: 100
own value (to
be entered!)
Relationship to
parameter:
33,031
33,011
The percental current threshold (in relation to motor current 33,031) at the
33.011
I
2
T time
Unit: s
min: 0
max.: 30
Relationship to
parameter:
Parameter manual:
p. xy
Transfer status:
2
def.: 25
own value (to
be entered!)
33.138
Holding current time
Unit: s
min: 0
max.: 120
Parameter manual:
p. xy
Transfer status:
2
def.: 2
own value (to
be entered!)
Relationship to
parameter:
33,010
Only for asynchronous motors.
This is the time span during which the drive is held with continuous current