8
SHOCK ABSORBER, SWINGARM
49
200268-10
–
When the pressure gauge reaches the specified value, turn the
Damper
control
lever
4
to
Pressure
.
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge rises to the specified value.
3 bar
200269-10
–
When the pressure gauge reaches the specified value, turn the
Damper
4
control
lever to
Vacuum
.
Guideline
3 bar
The pressure gauge falls to the specified value.
0 bar
–
When the pressure gauge reaches the specified value, operate the
On/Off
switch.
Guideline
0 bar
The vacuum pump is switched off.
201284-10
–
Slide O-ring
B
to the end of the special tool by the specified value (distance
A
minus specified value).
Guideline
10 mm
Depth micrometer (T107S) (
p. 219)
–
Slide the floating piston into the reservoir to the shortened position using the spe-
cial tool.
Info
The floating piston must be positioned at exactly this point when the rod
is fully extended; otherwise, damage will occur during compression of the
shock absorber.
–
Remove the special tool.
201283-10
–
Remove adapter
1
from connection
2
of the vacuum pump.
Info
Hold the damper so that the filling port is at the highest point.
–
Remove the adapter.
–
Mount and tighten screw
9
.
Guideline
Filling port screw
M10x1
14 Nm
(10.3 lbf ft)
8.21
Filling the damper with nitrogen
201282-10
–
Screw in screw
1
by approx. 2 rotations but do not tighten.
Info
The piston rod is fully extended.
Содержание 2011 690 SMC AUS
Страница 1: ...REPAIR MANUAL 2011 690 SMC EU 690 SMC AUS UK Art no 3206122en ...
Страница 2: ......
Страница 33: ...7 HANDLEBAR CONTROLS 31 Tighten counter nut 1 ...
Страница 69: ...11 FUEL TANK SEAT TRIM 67 Set the clock p 94 ...
Страница 186: ...24 SERVICE SCHEDULE 184 One time interval Periodic interval ...
Страница 187: ...185 ...
Страница 229: ... 3206122en 3206122en 10 2012 KTM Sportmotorcycle AG 5230 Mattighofen Austria http www ktm com Photo Mitterbauer KTM ...