Sequencer mode
252
SEQ P7–3: KARMA 3
7–3–1: GE RTP M–A
(GE Real-Time Parameters Master A)
Here you can edit the Real-Time Parameters of the GE for
each KARMA Module A. In addition, you can assign GE
Real-Time Parameters to the KARMA Real-Time Controls so
that you can control the phrase or pattern in real-time while
you play.
7–3–1a: GE Number & Name, GE RTC
Select, Tempo
GE Number & Name
GE RTC Select
[1–8, 9–16, 17–24, 25–32]
For more information, please see “7–3–1a: GE Number &
Name, GE RTC Select, Tempo” on page 171.
(Tempo)
[040.00...300.00, EXT]
For more information, please see “
7–3–1b: GE Real-Time Parameters for
Module Control = Master
GE RT Parm 1–8, 9–16,17–24, 25–32:
GE RT PARAM(GE Real-time Parameter)
MIN (GE Real-time Parameter Minimum Value)
[–5000…+5000]
MAX (GE Real-time Parameter Maximum Value)
[–5000…+5000]
VALUE (GE Real-time Parameter Value)
[–5000…+5000]
ASSIGN (GE Real-time Parameter Assign)
[---, SL1…8, SL1s…8s, SW1…8, Dyn1…8]
POL (GE Real-time Parameter Polarity)
[+, –]
For more information, please see “GE RT Parm 1–8, 9–16,
17–24, 25–32:” on page 171.
Note: Normally, the MIN, MAX, VALUE, and POL
parameters of each module are specified in module A, B, C,
and D. These parameter settings are possible if you specify
ASSIGN
in Master A, B, C, and D.
For example, if you want to use Slider1 to control the GE
REALTIME PARAMETER No.1 of Modules A, B, C, and D
when Module Control is set to Master, you would set the
Master, A, B, C, and D’s GE REALTIME PARAMETER No.01
ASSIGN
to Slider1. If these are set to ASSIGN, you are able
to edit the MIN, MAX, VALUE, and POL parameters for
Master, A, B, C, and D.
In this way, you can make GE realtime parameter settings
independently of Modules A, B, C, and D.
▼
7–3–1: Menu Command
• 0: Memory Status
• 2: Exclusive Solo
• 3: Copy KARMA Module
• 5: Copy Scene
• 6: Swap Scene
• 7: Capture Random Seed
• 8: FF/REW Speed
• 9: Set Location (Set Location for Locate Key)
• 10: Copy from Program
For more information, please see “Sequencer: Menu
Command” on page 271.
7–3–2: GE RTP M–B,
7–3–3: GE RTP M–C,
7–3–4: GE RTP M–D
(GE Real-Time Parameters Master B, C, D)
Here you can edit the parameters of the GE selected by
Module Control=Master for KARMA modules B, C, and D.
For more information, please see “7–3–1: GE RTP M–A (GE
Real-Time Parameters Master A),” above.
7–3
–1a
7–3
–1b
7–3
–1
Menu
Содержание M3
Страница 1: ...4 E ...
Страница 306: ...Sequencer mode 296 ...
Страница 364: ...Sampling mode 354 ...
Страница 430: ...Media mode 420 ...
Страница 534: ...Effect Guide 524 ...
Страница 646: ...Appendices 636 ...