Combination mode
136
Once the Program has been loaded, you can change any or
all of the Tone Adjust settings as desired, including both
assignments and values. All such edits are stored in the
Combination, without affecting the original Program.
If Auto Load PRG is On, Tone Adjust settings will be
automatically loaded along with the Program.
If Auto Load PRG is Off, then the relationship between the
types of the old and new Programs will determine what
happens., as shown in the table below:
Note: The EXB-RADIAS option must be installed in order to
use RADIAS programs.
Selected parameter information
This status line shows detailed, read-only information about
the currently selected Tone Adjust parameter.
Control
[SW1…8, SL1…8]
This is the physical controller assigned to the Tone Adjust
parameter.
Assignment
[List of Tone Adjust assignments]
This shows the full name of the parameter assigned to the
controller. You can change this using the “Assign”
parameter, below.
Value
This shows the current value of the parameter. The range of
values will vary depending on the parameter assigned to the
control.
Type
[Rel, Abs, Meta]
This shows the type of the parameter, which relates to how
edits to the parameter are saved. For more information,
please see “Absolute (Abs), Relative (Rel), Meta parameter”
on page 19.
Stored Value
This shows the original value of the parameter, before the
effects of Tone Adjust. It applies only to Tone Adjust
parameters which control a single Program parameter.
If you un-assign a parameter from a control, it will revert to
this value.
Switches 1...8
Tone Adjust switches act a little differently than sliders.
When a switch is assigned to a Relative parameter, or an
Absolute
parameter with more than two states:
Switch On = On Value (see below)
Switch Off = the Program’s stored value
When a switch is assigned to a two-state Absolute
parameter, such as Hold, the switch status directly reflects
the parameter value:
Switch On = On
Switch Off = Off
Assign
This lets you assign a Tone Adjust parameter to the switch.
The first group of parameters are the Common set, which
are supported by most Program types. For a full list, please
see “Common Tone Adjust Parameters” on page 21.
After the Common parameters, the items in the list will vary
depending on the Program type. For more information,
please see:
“Tone Adjust Parameters” on page 22
“EXB-RADIAS for M3 Manual” (PDF)
EDS, and RADIAS will have their own set of parameters, as
described in their manuals.
On Value
[Depends on parameter]
The parameter is set to this value when the switch is On.
When the switch is assigned to a two-state Absolute
parameter, such as Hold, this will always be the same as the
Switch Status
(see below).
Switch Status
[Off, On]
This simply shows whether the switch is On or Off. The
status is also shown by the LEDs in the physical buttons.
Sliders 1–8
Assign
This lets you assign a Tone Adjust parameter to the slider.
The first group of parameters are the Common set, which
are supported by most Program types. For a full list, please
see “Common Tone Adjust Parameters” on page 21.
After the Common parameters, the items in the list will vary
depending on the Program type. For more information,
please see:
“Tone Adjust Parameters” on page 22
“EXB-RADIAS for M3 Manual” (PDF)
EDS, and RADIAS will have their own set of parameters, as
described in their manuals.
Assignments are exclusive
Per-Oscillator parameters apply to OSC1 and 2 individually,
and are marked as such: OSC1 and OSC2.
Each controller can be assigned to only one parameter, and
each parameter can be assigned to only one controller.
To swap a parameter from one control to another, you’ll
need to first un-assign it from the old control, and then
assign it to the new control.
Value
This shows the current value of the parameter. The range of
values will vary depending on the parameter assigned to the
control.
If the old Program
is…
And the new
Program is…
Then Tone Adjust
parameters and
values are…
An EDS Program
An EDS Program
kept the same
An EDS Program
A RADIAS Program
loaded from the new
Program
A RADIAS Program
An EDS Program
loaded from the new
Program
A RADIAS Program
A RADIAS Program
kept the same
Control
Assignment
Value
Stored Value
Type
Assign
On/Off
Value
Содержание M3
Страница 1: ...4 E ...
Страница 306: ...Sequencer mode 296 ...
Страница 364: ...Sampling mode 354 ...
Страница 430: ...Media mode 420 ...
Страница 534: ...Effect Guide 524 ...
Страница 646: ...Appendices 636 ...