C
HAPTER
2 - I
NSTALLATION
BDS5
2-24
If the motor rotated to the wrong position, then you
must stop and correct this problem. Either the resolver
is improperly wired, the motor is improperly wired,
the motor is not functioning properly, or the resolver is
not functioning properly. In most cases, the wiring is
the problem. Check your motor and resolver wiring
carefully. Follow the procedure in "Checking the
Resolver Cable" in section 2.7.10. If you have wired
the motor through motor-overload relays, verify that
the relay is closed. Contact the factory if your motor
does not rotate to the zero position and you can not
correct the problem.
DO NOT PROCEED IF YOUR
MOTOR IS NOT ZEROING
PROPERLY.
WARNING