resistors, while others may require none at all. To
determine if your PSR4/5 has internal regen resistors,
check its model number.
REGEN RESISTORS GET
HOT!
If your PSR4/5 has internal
regen resistors, allow
sufficient clearance above the
PSR4/5.
Refer to Drawing A-93703 for
more information concerning
mounting.
Refer to appropriate outline and dimension drawings
in Appendix B for more information:
A-93569BDS5 3 and 6 Amp Unit
A-93571BDS5 10 Amp Unit
A-93570BDS5 20 Amp Unit
A-93880BDS5 30 and 40 Amp Unit
A-93010BDS5 55 Amp Unit
A-93581PSR4/5 12 and 20 Amp Unit
A-93031PSR4/5 50 and 75 Amp Unit
2.5.3 Mounting the External Regen
Resistor
External mounting of regen resistors is an option on
PSR4/5's. To determine if your unit uses external
regen resistors, check its model number. Also, the
model number indicates the standard resistor value.
These resistors should be enclosed to reduce shock
hazard. Regen resistors get hot! They are a burn
hazard and they are a fire hazard. They can produce
enough heat to melt insulation. Enclose these
resistors! The enclosure must provide ventilation and
withstand high temperatures. Do not mount the
resistors underneath the BDS5 or PSR4/5.
EXTERNAL REGEN
RESISTORS ARE A SHOCK
HAZARD!
Mount these resistors
properly! Enclose these
resistors to protect personnel
and equipment!
EXTERNAL REGEN
RESISTORS GET HOT!
If you are using external regen
resistors, allow sufficient
clearance around the
resistors. Enclosures must
provide ventilation.
2.6 WIRING
The customer is responsible for providing proper
circuit breaker or fuse protection. The customer is
responsible for providing proper wire gauge and
insulation rating for all wiring, including motor, AC
line, DC bus, and External Regen Resistor
connections. The customer is responsible for making
sure that all system wiring and electrical protection
comply with all applicable national and local electric
codes.
Drawing A-93103 is the System Wiring Diagram. It is
a seven-sheet drawing. Carefully read all of Drawing
A-93103 before wiring your BDS5 system, including
all of the notes on the last sheet. Refer to BDS5
Connectors Diagram A-96372M, provided at the end
of this chapter, for connector locations.
Carefully read all seven
sheets of Drawing A-93103
before wiring your BDS5
system, including ALL of the
notes on the last sheet.
When wiring your BDS5 system, observe the
following guidelines:
1.
Twist all AC leads to minimize electromagnetic
emissions (noise).
CAUTION
CAUTION
WARNING
WARNING
NOTE
Содержание BDS5
Страница 2: ......
Страница 3: ...BDS5 INSTALLATION AND SETUP MANUAL Old Number M93101 ISSUE 4 New Number MB5000H...
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 18: ......
Страница 20: ......
Страница 62: ...CHAPTER 2 INSTALLATION BDS5 2 26...
Страница 73: ...BDS5 CHAPTER 4 MAINTENANCE...
Страница 74: ...CHAPTER 4 MAINTENANCE BDS5...
Страница 78: ...CHAPTER 4 MAINTENANCE BDS5 4 4...
Страница 86: ...APPENDIX A WARRANTY INFORMATION BDS5 A 2...
Страница 88: ...APPENDIX B DRAWINGS BDS5 B 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 116: ......
Страница 131: ...APPENDIX E ON LINE REFERENCE GUIDE BDS5 E 2...