PWX
67
3
External Con
trol
Controlling the Output Voltage
This section explains how to control the output voltage using an external voltage (Vext) or an
external variable resistor (Rext) of approximately 10 k
Ω
.
If no load is connected, it takes some time for the output voltage to decrease.
Control using an external voltage (Vext)
To use an external voltage (Vext) to control the output voltage, set the CV control using an
external voltage or an external resistance in the CONFIG settings so that external voltage con-
trol is enabled (CF06: on).
The output voltage (Eo) varies in the range of 0 to the rated output voltage (Ertg) when the
external voltage (Vext) is changed in the range of 0 V to 5 V (CF07: Lo) or in the range of 0 V
to 10 V (CF07: Hi).
External voltage (Vext) connection
Use a low-noise, stable voltage source
for Vext. The noise in Vext is multiplied
by the amplification factor of the PWX
series and appears in the output.
Therefore, the output ripple noise may
not meet the specifications of the
PWX series.
To reduce the influence of noise on the
output, connect a 2-core shielded wire
or a twisted-pair wire across Vext, and
keep the wire as short as possible. If
the wiring between the PWX series and the external contact is long, it becomes easy for
noise to influence the operation of the PWX series. Even if you use cables that are designed
to suppress noise, the PWX series may not operate properly.
WARNING
Risk of electric shock.
• The insulation of Vext or Rext and the connected cable must be greater than or equal
to the isolation voltage of the PWX series.
For the isolation voltage of each model, ”Specifications” on page 93.
• When using shielded cables for the connection, protect the uncovered sections of
the shielded cable by using insulation tubes whose withstand voltage is greater than
the PWX series isolation voltage.
See
External voltage (Vext) 0 V to 5 V (CF07: Lo)
External voltage (Vext) 0 V to 10 V (CF07: Hi)
Eo = Ertg × Vext/5 (in V)
Vext = 5 × Eo/Ertg (in V)
Eo = Ertg × Vext/10 (in V)
Vext = 10 × Eo/Ertg (in V)
CAUTION
• The signal cable may burn out. Do not connect the Vext output, that is, leave it floating.
Risk of damage to the product.
• Pay careful attention to the polarity of Vext.
• Do not apply a voltage of 10.5 V or greater, or a reverse voltage across the external voltage
control pins.
• When using the optional isolated analog interface, do not connect anything to pin 22
(VPGM) of the J1 connector.
2-core shielded wire or
twisted-pair wire
Vext
+
–
Output terminals
J1
22
23
PWX
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...