PWX
59
2
Basic Functions
Switching from Remote Mode to Local Mode
When the PWX series is being controlled remotely, the REMOTE LED in the display area
lights.
To switch the PWX series to local mode from the front panel, press LOCAL.
Factory Default Settings (Initialization)
If you hold down SHIFT+LOCAL while you turn the POWER switch on, the PWX series will be
reset to the factory default settings.
The factory default settings are shown below.
Basic settings
Lit
Basic item
Parameter description
Outputvoltage
0 V
Outputcurrent
105 % of the rated output current
OVP (overvoltage protection)
112 % of the rated output voltage
OCP (overcurrent protection)
112 % of the rated output current
UVL (undervoltage limit)
0 V