58
PWX
Bleeder On/Off Feature
Sink current from an external voltage source when the breeder is on and
off (When the voltage from the external voltage source is larger than the
set voltage)
Fall time of the output voltage when the breeder is off
This is the time period for the rated output voltage to fall from 90 % to 10 % when the out-
put is changed from on to off under no load conditions.
Vout = Output terminal voltage
Model
Bleeder
circuit
Sink current
5 Vout
1
10 Vout
15 Vout
20 Vout
25 Vout
30 Vout
PWX750LF
ON
704 mA
667 mA 630 mA 593 mA 556 mA 519 mA
OFF
0.2 mA
0.4 mA
0.6 mA
0.8 mA
1.0 mA
1.2 mA
PWX1500L
ON
704 mA
667 mA 630 mA 593 mA 556 mA 519 mA
OFF
0.2 mA
0.4 mA
0.6 mA
0.8 mA
1.0 mA
1.2 mA
Vout = Output terminal voltage
Model
Bleeder
circuit
Sink current
5 Vout
10 Vout
20 Vout
30 Vout
40 Vout
50 Vout
60 Vout
70 Vout
80 Vout
PWX750MLF ON
714 mA
682 mA 620 mA 558 mA 496 mA 433 mA 371 mA 309 mA 246 mA
OFF
0.2 mA
0.3 mA
0.5 mA
0.7 mA
0.9 mA
1.1 mA
1.3 mA
1.5 mA
1.7 mA
PWX1500ML ON
583 mA
559 mA 510 mA 462 mA 414 mA 365 mA 317 mA 269 mA 221 mA
OFF
0.2 mA
0.3 mA
0.5 mA
0.7 mA
0.9 mA
1.1 mA
1.3 mA
1.5 mA
1.7 mA
Vout = Output terminal voltage
Model
Bleeder
circuit
Sink current
10 Vout
20 Vout
50 Vout 100 Vout 200 Vout 230 Vout
PWX750MHF ON
746 mA
549 mA 307 mA 177 mA
96 mA
84 mA
OFF
0.2 mA
0.3 mA
0.7 mA
1.3 mA
2.5 mA
2.9 mA
PWX1500MH ON
1097 mA 808 mA 451 mA 260 mA 140 mA 123 mA
OFF
0.3 mA
0.5 mA
1.3 mA
2.5 mA
5.0 mA
5.8
Vout = Output terminal voltage
Model
Bleeder
circuit
Sink current
20 Vout
50 Vout 100 Vout 200 Vout 300 Vout 400 Vout 500 Vout 600 Vout 650 Vout
PWX750HF
ON
309 mA
217 mA 145 mA
87 mA
62 mA
48 mA
40 mA
33 mA
31 mA
OFF
0.2 mA
0.3 mA
0.6 mA
1.2 mA
1.8 mA
2.4 mA
3.0 mA
3.6 mA
3.9 mA
PWX1500H
ON
463 mA
325 mA 217 mA 130 mA
93 mA
73 mA
59 mA
50 mA
47 mA
OFF
0.2 mA
0.5 mA
0.9 mA
1.7 mA
2.5 mA
3.4 mA
4.2 mA
5.0 mA
5.5 mA
1
Even when the breeder is on, the sink current decreases gradually at output terminal voltages lower than this
voltage. If the output terminal voltage is near 0 V, hardly any current will be sunk even when the breeder is on.
Model
Fall time
Model
Fall time
PWX750LF
310 seconds
PWX1500L
490 seconds
PWX750MLF
280 seconds
PWX1500ML
460 seconds
PWX750MHF
110 seconds
PWX1500MH
130 seconds
PWX750HF
70 seconds
PWX1500H
100 seconds
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...