20
PWX
Connecting to the Output Terminals
1
Turn the POWER switch off.
Check that there is no voltage across the output terminals.
2
Connect one end of the included chassis connection wire to the chassis
terminal, and then connect the other end of the wire to the negative or
positive output terminal.
Use the screw on the PWX to connect the wire to the chassis terminal. Use the screw
on the output terminal to connect the wire to the output terminal.
WARNING
Risk of electric shock.
• Turn the POWER switch off before you touch the OUTPUT terminals.
• Even if you turn the output off or turn the POWER switch off, if the bleeder on/off set-
ting (CF11) is set to “oFF,” the voltage that was present when the output was on will
remain at the output terminals. Set the bleeder on/off setting to “on” before you
touch the output terminals.
• Regardless of whether load cables are connected to the output terminals, be sure to
attach the OUTPUT terminal cover before turning the POWER switch on.
Chassis terminal
- (negative) terminal
+ (positive) terminal
The PWX1500ML is in this example.
Chassis
connection wire
Screw (M3)
Screw (M4)
Chassis
connection wire
Screw (M3)
Screw (M4)
Target model
PWX750LF
PWX750MLF
PWX1500L
PWX1500ML
Target model
PWX750MHF
PWX750HF
PWH1500MH
PWX1500H
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...