PWX
17
1
Inst
allation
and Prep
aratio
n
Load Considerations
Note that the output will become unstable if the following types of loads are connected.
Loads with peak current or pulse-shaped current
The PWX series only indicates mean values. Even when the indicated value is less than or
equal to the set constant current, the peak values may exceed the set constant current. If this
happens, the PWX series is instantaneously put into constant-current mode, and the output
voltage drops.
For these types of loads, you must increase the set constant current or increase the current
capacity.
Loads that generate reverse current to the power supply
The PWX series cannot absorb reverse current from the load. Therefore, if a regenerative
load (such as an inverter, converter, or transformer) is connected, the output voltage
increases and becomes unstable. This can cause a malfunction.
For these types of loads, connect a resistor (R
D
) as shown in the following figure to bypass
the reverse current. However, the amount of current to the load decreases by Irp.
Load current with peaks
Pulse-shaped load current
Set constant current
Ammeter reading (mean value)
Set constant current
Ammeter reading (mean value)
I
O
R
D
E
O
Equivalent circuit of the PWX750ML
Regenerative load
+
0
Reverse current
-
I
O
+
I
O
I
rp
R
D
(in Ω) ≤
R
D
: Reverse current bypass dummy load
E
O
: Output voltage
Irp: Maximum reverse current
EO (in V)
Irp (in A)
Load
Output current
CAUTION
Use a resistor with sufficient rated power for R
D
. If a resistor with insufficient rated power for
the circuit is used, resistor R
D
will burn out.
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...