PWX
63
About the J1 Connector
External Con
trol
3
J1 connector pin arrangement
Connector type
5747461-3 (AMP)
Plug type
745211-7 (AMP)
Wire diameter
AWG26 to AWG22
Manual pressure weld-
ing tool
AMP handle assembly 58074-1
AMP head assembly 58063-2
Insertion/extraction tool
AMP 91232-1 or equivalent
J1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Pin number positions when you are
facing the rear panel
Pin
no.
Signal name
Description
1
STATUS COM
Status signal common for pins 2, 3, and 14 to 16.
1
2
CV STATUS
On when the PWX series is in CV mode (open-collector output from a photocoupler).
2
3
CC STATUS
On when the PWX series is in CC mode (open-collector output from a photocoupler).
4
N.C.
Not connected.
5
ALM CLR
Alarm clear terminal.
Alarms are cleared when a LOW (0 V to 0.5 V) or short-circuit is applied to this terminal.
6
SHUT DOWN
Output shutdown control terminal. The output is turned off when a LOW (0 V to 0.5 V) or short-circuit is
applied to this terminal.
7
PRL IN-
Negative input terminal for master-slave parallel operation.
8
PRL IN+
Positive input terminal for master-slave parallel operation.
9
PRL COMP IN
Correction signal input terminal for master-slave parallel operation.
10
A COM
External signal common for pins 5 to 9, 11 to 13, 20 to 22, 24, and 25.
During remote sensing, this is the negative electrode (-S) of sensing input. When remote sensing is not
being performed, this is connected to the negative output.
11
PRL OUT+
Positive electrode output terminal for master-slave parallel operation.
12
PRL COMP OUT
Correction signal output terminal for master-slave parallel operation.
13
I SUM
Current signal terminal for master-slave parallel operation.
14
ALM STATUS
On when a protection function (OVP, OVP2, OCP, OHP, OHP2, FAN, SEN, or AC_FAIL) has been acti-
vated or when an output shutdown signal is being applied (output through an open-collector photocou-
pler).
15
PWR ON STATUS Outputs a low level signal when power is turned on (output through an open-collector photocoupler).
16
OUT ON STATUS
On when output is on (output through an open-collector photocoupler).
17
N.C.
Not connected.
18
OUT ON/OFF
CONT
Output on/off terminal.
On when set to LOW (0 V to 0.5 V) or shorted; off when set to HIGH (4.5 V or 5 V) or open (CF10: Lo)
On when set to HIGH (4.5 V to 5 V) or open; off when set to LOW (0 V or 0.5 V) or shorted (CF10: Hi)
19
A COM
External signal common for pins 5 to 9, 11 to 13, 20 to 22, 24, and 25.
During remote sensing, this is the negative electrode (-S) of sensing input. When remote sensing is not
being performed, this is connected to the negative output.
20
REF OUT
External resistance control terminal; 5.25 V (CF07: Lo) or 10.5 V (CF07: Hi). The maximum output current
2.5 mA.
21
I PGM
Terminal used to control the output current with an external voltage or external resistance.
0 V to 5 V; 0 % to 100 % of the rated output current (CF07: Lo).
0 V to 10 V; 0 % to 100 % of the rated output current (CF07: Hi).
22
V PGM
Terminal used to control the output voltage with an external voltage or external resistance.
0 V to 5 V; 0 % to 100 % of the rated output voltage (CF07: Lo).
0 V to 10 V; 0 % to 100 % of the rated output voltage (CF07: Hi).
23
A COM
External signal common for pins 5 to 9, 11 to 13, 20 to 22, 24, and 25.
During remote sensing, this is the negative electrode (-S) of sensing input. When remote sensing is not
being performed, this is connected to the negative output.
24
I MON
Output current monitor.
0 % to 100 % of the rated output current is generated as a voltage between 0 V and 5 V (CF08: Lo) or a
voltage between 0 V and 10 V (CF08: Hi).
25
V MON
Output voltage monitor.
0 % to 100 % of the rated output voltage is generated as a voltage between 0 V and 5 V (CF08: Lo) or a
voltage between 0 V and 10 V (CF08: Hi).
1
The status common is floating (isolation voltage of 60 V or less), it is isolated from the control circuit. If connected for master-slave
parallel operation, STATUS COM of the master unit will be connected to A COM of the slave unit (it will no longer be floating).
2
Open collector output:Maximum voltage of 30 V and maximum current of 8 mA.
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...