PWX
105
PWX1500L/ PWX1500ML/ PWX1500MH/ PWX1500H
6
S
pe
cificati
ons
Output
PWX1500L
PWX1500ML
PWX1500MH
PWX1500H
Rating
Output voltage
1
1
The maximum output voltage and current are limited by the maximum output power.
30 V
80 V
230 V
650 V
Output current
150 A
56 A
20 A
7 A
Output power
1500 W
Voltage
Setting range
0 V to 31.5 V
0 V to 84 V
0 V to 241.5 V
0 V to 682.5 V
Setting accuracy
±(0.05 % of set +0.05 % of rtg)
Line regulation
2
2
85 Vac to 135 Vac or 170 Vac to 265 Vac, fixed load.
±5 mV
±10 mV
±25 mV
±67 mV
Load regulation
3
3
The amount of change that occurs when the load is changed from no load to rated load (rated output power/rated
output voltage) with rated output voltage. The value is measured at the sensing point.
±5 mV
±10 mV
±25 mV
±67 mV
Transient response
4
4
The amount of time required for the output voltage to return to a value within “rated output voltage ± (0.1 % +
10 mV).” The load current fluctuation is 50 % to 100 % of the maximum current with the set output voltage.
1 ms or less
7 ms or less
Ripple noise
5
5
Measured using an RC-9131B 1:1 probe that conforms to the JEITA specifications. At the rated output current.
(p-p)
6
6
When the measurement frequency bandwidth is 10 Hz to 20 MHz.
60 mV
80 mV
120 mV
330 mV
(rms)
7
7
When the measurement frequency bandwidth is 5 Hz to 1 MHz.
8 mV
8 mV
25 mV
60 mV
Rise time
Rated load
100 ms
No load
100 ms
Fall time
8
8
When the breeder circuit on/off setting is on.
Rated load
100 ms
150 ms
250 ms
No load
800 ms
1500 ms
3000 ms
Maximum remote sensing com-
pensation voltage (single line)
1.5 V
4 V
5 V
5 V
Temperature coefficient (MAX)
9
9
When the ambient temperature is within 0 °C and 50 °C
100 ppm/°C (during external control)
Current
Setting range
0 A to 157.5 A
0 A to 58.8 A
0 A to 21 A
0 A to 7.35 A
Setting accuracy
10
10
For the PWX1500H, in the range of 0.2 % to 100 % of the rated current.
±(0.5 % of set +0.1 % of rtg)
Line regulation
±17 mA
±7.6 mA
±4 mA
±2.7 mA
Load regulation
±35 mA
±16.2 mA
±9 mA
±6.4 mA
Ripple noise
11
11
When the output voltage is 10 % to 100 % of the rating.
At the rated output current.
300 mA
130 mA
60 mA
30 mA
Temperature coefficient (TYP)
100 ppm/°C
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...